81 1-800-526-2324 ? www.us.tdk-lambda.com/lp/ disclaimer: us.tdk-lambda.com/lp/legal.htm nv175 series features ? 1-5 outputs ? up to 90% ef cient ? active power factor correction ? universal input (90 - 264vac) ? no minimum loads ? medical approvals (basic insulation input-output) 3? x 5? 175-200w power supplies model nv175 input voltage range - 90 - 264vac (47 - 63hz, 440hz with reduced pfc) inrush current a <40a at 25c and 264vac input, cold start power factor harmonics - en61000-3-2 compliant (0.97 typical) regulation total - 1%; including line (for 90-264vac input change), load (for 0-100% load change) and cross (for 0-100% load change on any other output) regulation ripple & noise mv 1% or 50mv (which ever is greater) ef ciency - up to 90%, con guration dependant minimum load a none overcurrent protection - >105% overvoltage protection v ch1 & ch2, 120-130%, cycle ac line to reset overtemperature protection - yes hold up time (typ) ms >16ms at 90vac input leakage current (max) a 123 a 120vac 60hz, 257 a 240vac 60hz, <300 a 264vac 63hz (type test results) remote sense - on outputs ch1 & ch2, 0.5v compensation maximum dc good - ch1 only, high on fail (90% of nominal 5%) remote on/off (specify n option) - -n1 or -n2 option: ttl level high = off, -n3 or -n4 option: open circuit = off (except standby) operating temperature (1)(7) - 0 to +70c. derate linearily to 50% load from 50c to 70c storage temperature - -40 to +85c humidity (non condensing) - 5 - 95% rh cooling - forced air, 2m/s from input to output (approx 10 cfm) isolation (4) - input to ground 2.3kvdc, input to output 4.3kvdc, output to ground 200vdc vibration (non operating) - conforms to mil-std-810e, method 516.5, pro i, iv, vi; en60068-2-6, iec68-2-6 shock - conforms to mil-std-810e/f, method 514.4, pro i, cat 1,9; en60068-2-27, en60068-2-47, iec68-2-47, iec68-2-47, jis c0041-1987 safety agency approvals - ul/csa/iec/en 60950-1, ul/csa/iec/en 60601-1, ansi/aami es60601-1, iec/en 61010-1, ce mark immunity - en61000-6-2:2001, en61000-4-2, -3, -4, -5, -6, -8, -11 conducted emissions and flicker - en55022 class b (per cispr.22), en61000-3-3 radiated emissions (2) - en55022 class a (per cispr.22) weight (typ) g 250g size (without cover) (3) in 3? x 5? x 1.25?; n option version 3.7? x 5? x 1.25? warranty yrs three years speci cations (1) -20c cold start (2) see application note for class b (3) including underside component leads (4) input-output: reinforced iec60950-1, basic iec 60601-1. see nv175-m for reinforced medical insulation key market segments & applications
82 1-800-526-2324 ? www.us.tdk-lambda.com/lp/ revision c9: jul 2014 nv175 series for additional information, please visit us.tdk-lambda.com/lp/products/nv-series.htm ch1 ch1(5) adjust. ch2 adjust. ch3 adjust. ch4 adjust. code range ch2(5) code range ch3 code range ch4 code range +5v / 25a 5 5 - 5.5v +1.8v / 15a 1 0.9 - 3.3v -12v / 1a t fixed +2.7v / 15a 2 2.5 - 3.3v -15v / 1a f fixed +3.3v / 15a 3 2.5 - 3.3v -3.3v / 2a 3h fixed no output 0 - -5v / 2a 5h fixed +12v / 5a t 12 - 15v -12v / 2a th fixed +15v / 5a f 12 - 15v -15v / 2a fh fixed +24v / 2.5a g 18 - 24v fan supply only 0h fixed +12v / 15a t 12 - 15v (8) +5v / 10a 5 3.3 - 5.5v no output 0 - no output 0 +15v / 12a f 12 - 15v (9) no output 0 - add ?p? to add ?p? to code code for +24v / 7.5a g 24 - 28v (10) +5v / 8a 5 3.3 - 5.5v for positive positive no output 0 - polarity output polarity output built to order model selector how to create a model number example nv1 3 g 5 0 3hp n c description: triple output, 24v/7.5a, 5v/8a, 3.3v/2a, global option n, u chassis with cover. no option blank blank no case ac fail, remote on/off, 5v/2a standby, ch1 dc good n u u chassis ac fail, remote on/off, 12v/1a standby, ch1 dc good n1 c u chassis with cover ac fail, remote on/off, 13.5v/1a standby, ch1 dc good n2 f u chassis, cover and fan* atx ac fail+remote on/off, 5v/2a standby, ch1 dc good n3 i u chassis, cover and fan* atx ac fail+remote on/off, 12v/1a standby, ch1 dc good n4 and iec inlet * a high output ch4 (3h, 5h, th, fh) or fan supply 0h must be selected to provide fan option. nv1- enter number of outputs ch1 ch2 ch3 ch4 global case code code code code option option nv 300 to 700w medical, 1-6 outputs sc40/60 40 to 80w single, dual & triple 3x5 footprint zws/zwspaf 5 to 240w single output power supplies other industrial products ch5 global ch1 ch2 ch3 ch4 stand by option model (5) (5) (6) type nv1-1t000 12v/15a - - - - - nv1-1g000 24v/7.5a - - - - - nv1-453tt +5v/25a +3.3v/15a +12v/5a -12v/1a - - nv1-453ff +5v/25a +3.3v/15a +15v/5a -15v/1a - - nv1-4g5tt +24v/7.5a +5v/8a +12v/5a -12v/1a - - nv1-4g5ff +24v/7.5a +5v/8a +15v/5a -15v/1a - - nv1-453tt-n3 +5v/25a +3.3v/15a +12v/5a -12v/1a 5v/2a n3 (atx) nv1-453ff-n3 +5v/25a +3.3v/15a +15v/5a -15v/1a 5v/2a n3 (atx) nv1-4g5tt-n3 +24v/7.5a +5v/8a +12v/5a -12v/1a 5v/2a n3 (atx) nv1-4g5ff-n3 +24v/7.5a +5v/8a +15v/5a -15v/1a 5v/2a n3 (atx) notes: (5) maximum combined current from ch1 + ch2 = 25a 5v ch1 models are limited to 175w max. all others 180w, 200wpk 5 mins (6) ch5 is always on regardless of inhbit status. peak rated at 2.5a, oating output (7) convection cooled maximum ratings: ch1: 55w, ch2: 8.25w, ch3: 9w, ch4: 3w, 75.25w total. 0c - 40c temperature range (8) 12 - 12.5v if 24v ch3 is tted. (9) 14.5 - 15.5v if 24v ch3 is tted. (10) 24 - 24.5v if 5v ch2 is tted. 24 - 26v if 24v ch3 is tted stocked models quick selector outline drawing conn housing pins j1 39-01-2245 44476-3112 j2 09-50-8051 08-52-0113 mating parts (molex) see the website for detailed datasheet and outline drawing. add ?y? to code for negative polarity output
|